· Module 07

Relay and MOSFET Interfaces

Dr. Redmond R. Shamshiri
Assistant Professor of Robotics · University of Southern Denmark (SDU)

Study Relay and MOSFET Interfaces. Use the accompanying model, numerical example and practical task to connect the topic to a measurable engineering result. Notes are original supplemental material, not a transcript.

Learning Objectives

  • Explain the role of power distribution, inrush and decoupling in the engineering system.
  • Calculate the worked quantity with consistent units.
  • Design a measurement that can reveal an implementation failure.

Study guide

Original companion notes. These notes support the topic of this lesson. They are not a transcript or a claim about the exact contents, hardware settings or examples in the video.

Lesson focus: Relay and MOSFET Interfaces

Define the input, measured output, units and pass/fail condition before running the experiment.

Power distribution, inrush and decoupling

Motors and radios draw dynamic current. A supply that meets average power can still sag during startup and reset a controller. Separate the high-current path, measure at the actual device pins and account for wiring resistance and transient energy.

Model, units and assumptions

\[P=VI,\qquad\Delta V\approx I\Delta t/C,\qquad V_{drop}=IR_{wire}\]

The capacitor relation approximates a short current pulse supplied only by a capacitor and ignores ESR and regulator dynamics. Real decoupling design needs component and layout constraints as well as capacitance.

Worked engineering example

A 0.5 A pulse lasting 1 ms would cause a 0.5 V ideal drop on 1,000 µF if the capacitor alone supplied it. A 0.2 Ω round-trip cable adds 0.1 V drop at the same current.

Practical task and evidence

Apply the following procedure to the topic of this lesson: Relay and MOSFET Interfaces.

  • Measure voltage at the controller rail while the actuator starts.
  • Record peak current, brownout logs and the timing of resets.
  • Use a correctly rated supply and protection; add decoupling based on measured transient behavior.

Submit: a diagram or interface table, a short timestamped dataset, the calculation with units, and a paragraph explaining the largest observed limitation.

Check your understanding

Question. A 24 V load draws 2 A. What electrical input power is required?

Show worked answer

48 W before supply and conversion losses.

Extension. Change one assumption in the model and explain which measurement would reveal that it no longer holds.

Summary

Power distribution, inrush and decoupling: keep units, assumptions and timing explicit. Check the numerical model against an independent observation before using it in a larger system.

MARIAM: Mastering Automation and Robotics for Industrial Agricultural Management · Dr. Redmond R. Shamshiri · University of Southern Denmark (SDU)