· Module 21

Tracking Feasible Temperature Targets

Dr. Redmond R. Shamshiri
Assistant Professor of Robotics · University of Southern Denmark (SDU)

Study Tracking Feasible Temperature Targets. Use the accompanying model, numerical example and practical task to connect the topic to a measurable engineering result. Notes are original supplemental material, not a transcript.

Learning Objectives

  • Explain the role of thermal balance and feedforward in the engineering system.
  • Calculate the worked quantity with consistent units.
  • Design a measurement that can reveal an implementation failure.

Study guide

Original companion notes. These notes support the topic of this lesson. They are not a transcript or a claim about the exact contents, hardware settings or examples in the video.

Lesson focus: Tracking Feasible Temperature Targets

Define the input, measured output, units and pass/fail condition before running the experiment.

Thermal balance and feedforward

A thermal system stores heat while exchanging it with its surroundings. Fan action often changes heat transfer rather than directly setting temperature. Model the operating range and separate measured disturbances from feedback correction.

Model, units and assumptions

\[C_{th}\frac{dT}{dt}=P_{in}-hA(T-T_a)\]

Cth is thermal capacitance in J/K, Pin is net heat input in W, hA is effective conductance in W/K, and Ta is ambient temperature. The lumped model assumes the measured body is approximately isothermal.

Worked engineering example

With Pin = 20 W and hA = 2 W/K, the ideal steady temperature rise is 10 K. If Cth = 100 J/K, the first-order time constant is 50 s. Changing airflow may change hA and therefore both gain and time constant.

Practical task and evidence

Apply the following procedure to the topic of this lesson: Tracking Feasible Temperature Targets.

  • Measure ambient and process temperature with synchronized timestamps.
  • Apply small bounded heat or fan changes around one operating point.
  • Compare model predictions before and after an airflow or ambient disturbance.

Submit: a diagram or interface table, a short timestamped dataset, the calculation with units, and a paragraph explaining the largest observed limitation.

Check your understanding

Question. At steady state, Pin = 30 W and hA = 3 W/K. Find temperature rise.

Show worked answer

10 K above ambient under the lumped model.

Extension. Change one assumption in the model and explain which measurement would reveal that it no longer holds.

Summary

Thermal balance and feedforward: keep units, assumptions and timing explicit. Check the numerical model against an independent observation before using it in a larger system.

MARIAM: Mastering Automation and Robotics for Industrial Agricultural Management · Dr. Redmond R. Shamshiri · University of Southern Denmark (SDU)