· Module 36

Pole Placement and State Feedback

Dr. Redmond R. Shamshiri
Assistant Professor of Robotics · University of Southern Denmark (SDU)

Study Pole Placement and State Feedback. Use the accompanying model, numerical example and practical task to connect the topic to a measurable engineering result. Notes are original supplemental material, not a transcript.

Learning Objectives

  • Explain the role of poles, eigenvalues and stability in the engineering system.
  • Calculate the worked quantity with consistent units.
  • Design a measurement that can reveal an implementation failure.

Study guide

Original companion notes. These notes support the topic of this lesson. They are not a transcript or a claim about the exact contents, hardware settings or examples in the video.

Lesson focus: Pole Placement and State Feedback

Define the input, measured output, units and pass/fail condition before running the experiment.

Poles, eigenvalues and stability

Eigenvalues describe local dynamics of a linear model. Continuous-time and discrete-time stability regions differ. A stable nominal model does not by itself guarantee acceptable overshoot, robustness or safety with actuator saturation.

Model, units and assumptions

\[\dot x=Ax:\ \Re(\lambda_i)<0,\qquad x_{k+1}=A_dx_k:\ |\lambda_i(A_d)|<1\]

These strict conditions characterize asymptotic stability of finite-dimensional linear time-invariant systems. For an exactly sampled constant linear system, Ad = exp(A Ts). Nonlinear systems require additional analysis.

Worked engineering example

A continuous pole at −2 s⁻¹ maps at Ts = 0.1 s to exp(−0.2) ≈ 0.819, inside the unit circle. A discrete pole at −1.1 alternates sign and grows, so it is unstable despite its negative real value.

Practical task and evidence

Apply the following procedure to the topic of this lesson: Pole Placement and State Feedback.

  • Identify whether every reported pole is continuous or discrete.
  • Compare simulated responses with the decay or growth predicted by the poles.
  • Test sampling changes and actuator limits separately from nominal pole placement.

Submit: a diagram or interface table, a short timestamped dataset, the calculation with units, and a paragraph explaining the largest observed limitation.

Check your understanding

Question. Is a scalar discrete model with pole 0.95 asymptotically stable?

Show worked answer

Yes, because its magnitude is below one; it may nevertheless decay slowly.

Extension. Change one assumption in the model and explain which measurement would reveal that it no longer holds.

Summary

Poles, eigenvalues and stability: keep units, assumptions and timing explicit. Check the numerical model against an independent observation before using it in a larger system.

MARIAM: Mastering Automation and Robotics for Industrial Agricultural Management · Dr. Redmond R. Shamshiri · University of Southern Denmark (SDU)