Teaching guide

Inside the lettuce rack

Each tier grows lettuce under LEDs. A pump lifts nutrient solution from the reservoir. In the nutrient film technique (NFT), a thin film runs past the roots in sloping channels and drains back by gravity. Switch to Root zone to follow it.

Start the guided demo for a narrated tour of the rack, its four sensor stations and the growing crop. Check Record demo before starting to save your own video. Use Narration on/off to include or mute the voice.

Follow the control loop

SenseFlow meter and air probe
DecideLocal rack controller
ActPump and exhaust fan

The climate, water and light stations report every simulated second. The SCD41 CO₂ station reports every five simulated seconds. In Automatic mode, the controller compares the flow reading with its target and adjusts the pump. The air temperature determines the exhaust fan setting. Light intensity stays under your control in both modes.

Classroom experiments

Time a nutrient circuit

Release the amber tracer at the default flow target of 2.40 L/min. Follow it up the supply pipe, through the root channel and back to the reservoir. Now lower the target to 1.20 L/min, wait for the flow reading to settle and release it again. Predict the new return time before watching the pulse.

Find the limit of the pump

Start in Automatic and apply Partially blocked line. Compare pump output with the flow reading. Can the pump reach 2.40 L/min through the restriction? Select Normal operation and watch the recovery.

Watch the thermostat switch

Apply a Heat pulse and watch air temperature. At 24 °C, the controller boosts the fan to 90%. It returns to 30% when the rack cools to 22.5 °C. The gap between the two thresholds prevents rapid switching.

Separate light from heat

Open Canopy light and dim the LEDs. The light sensor responds on the next sample. Switch to air temperature to see the slower thermal response. Restore the lights to 60% and compare the recovery time. The light chart also projects the daily light integral for a 16-hour lighting day.

Compare rack growth with a single plant

Open Crop cycle and play the Whole rack view from transplant to harvest size. Pause on any day, then select Plant cutaway to see the roots and leaves at the same crop age.

Model assumptions and reading

This short-duration teaching model uses illustrative setpoints for one rack. Flow is the total delivered to all tiers. The exhaust exchanges room air with a 20 °C conditioned supply containing 700 ppm CO₂. The illustrative CO₂ balance includes crop respiration, light-dependent uptake and ventilation. The CO₂ reading lags behind changes in rack air. The EC probe monitors the reservoir’s electrical conductivity, which is held at 1.60 mS/cm during these experiments. EC reflects the overall dissolved ion content. Identifying individual nutrients requires other measurements. The tracer represents one path through the rack. Its travel time varies with actual flow, using an illustrative equivalent circuit volume of 4.2 L and the total rack flow. The animation uses a visible amber marker to show transport.

PPFD is the photosynthetic photon flux density at the canopy. Lowering the LED duty lowers the modeled PPFD immediately at the next sample. Temperature and humidity respond over time.

The crop time-lapse illustrates one 28-day sequence after transplanting. Cultivar and growing conditions affect actual harvest time. This sequence is independent of the live controller settings.

University of Saskatchewan · Hydroponic lettuce, nutrient film technique

University of Kentucky · Hydroponic lettuce production in controlled environments

Starting a controller or tracer experiment resets the rack to its baseline.