Study Drive one DC motor through an H-bridge. Use the accompanying model, numerical example and practical task to connect the topic to a measurable engineering result. Notes are original supplemental material, not a transcript.
Learning Objectives
- Explain the role of pwm and drive commands in the engineering system.
- Calculate the worked quantity with consistent units.
- Design a measurement that can reveal an implementation failure.
Study guide
Original companion notes. These notes support the topic of this lesson. They are not a transcript or a claim about the exact contents, hardware settings or examples in the video.
Lesson focus: Drive one DC motor through an H-bridge
Verify the electrical waveform and driver limits before interpreting motor motion.
PWM and drive commands
A power driver switches the motor supply; a controller supplies a low-power command. Duty cycle changes average applied voltage, while motor current and load determine the resulting speed. A GPIO must never power the motor directly.
Model, units and assumptions
D is duty ratio (0–1), T is the PWM period in seconds, f is frequency in hertz, and Vs is supply voltage. The average-voltage approximation assumes an ideal switch and a suitable motor driver; it does not imply a linear speed law under changing load.
Worked engineering example
At a 24 V supply and 35% duty, the ideal average command voltage is 8.4 V. At 20 kHz the period is 50 µs, so the on-time is 17.5 µs. Measure the actual waveform before attaching the motor.
Practical task and evidence
Apply the following procedure to the topic of this lesson: Drive one DC motor through an H-bridge.
- Use a current-limited supply and a rated driver; begin with the motor unloaded and mechanically secured.
- Scope the PWM output at 10%, 35% and 70%; record frequency, amplitude and on-time.
- Add a repeatable load and compare speed at fixed duty with speed under feedback.
Submit: a diagram or interface table, a short timestamped dataset, the calculation with units, and a paragraph explaining the largest observed limitation.
Check your understanding
Question. For a 12 V supply, 62.5% duty and 5 kHz switching, find average voltage and on-time.
Show worked answer
Average voltage ≈ 7.5 V. Period = 200 µs; on-time = 125 µs. Actual terminal voltage includes driver drops and switching transients.
Extension. Change one assumption in the model and explain which measurement would reveal that it no longer holds.