Product function
7-in-1 Soil Integration Sensor. Manufacturer model NBL-S-TMC-7.
Third-party product supplied by NiuBoL. Confirm the ordered configuration.
Core capabilities and practical value for deployment.
7-in-1 Soil Integration Sensor. Manufacturer model NBL-S-TMC-7.
Review the source-specific ranges, interfaces and operating conditions below when specifying your required configuration.
DC 5-24V
The overview and specification table retain supplier-document differences and applicable measurement limitations.
Detailed technical data for evaluation and system integration.
| Supply Voltage | DC 5-24V |
|---|---|
| Output | RS485 |
| Temperature range | -40-80 ℃ |
| Temperature accuracy | ±0.5 ℃ |
| Moisture range | 0%-100% |
| Moisture accuracy | ±5% |
| Conductivity range | 0-10000us/cm |
| Conductivity Accuracy | ±10% |
| NPK range | 0-2000mg/Kg |
| Accuracy of NPK | ±2% |
| PH range | 3-10pH |
| PH precision | ±0.6pH |
| Protection class | IP68 |
| Remark | Soil NPK sensor actually measures the electrical conductivity of the soil. |
| Soil temperature range | -40~80℃ Resolution: 0.1, Accuracy: ±0.5 |
|---|---|
| Soil moisture range | 0-100%RH Resolution: 0.1%RH, Accuracy: ±3% |
| Conductivity range | 0-10000us/cm.Accuracy: ±10% |
| NPK range: | 0-2000mg/Kg Accuracy of NPK: ±2% |
| PH effective range: | 3-10PH PH precision: ±0.6PH |
| Supply voltage | DC5V-24V □ DC12V-24V |
| Signal output | □RS485 |
| Protection class | Ip68 submerged in water for long-term use |
| Operating environment | -40~80℃ |
| Sealing material | Black flame retardant epoxy resin |
| Supplier statement | Lnstallation method: all buried or all probes are inserted into the measured medium |
| Supplier statement | Default cable length: 5 meters, cable length can be customized |
| Connection method | Pre-assembled cold-pressed terminals |
| Meamethodsurement principle: | Soil moisture FDR |
| Electrode length | 65mm |
| Measured outputs | Soil temperature, moisture, electrical conductivity, pH, nitrogen, phosphorus, potassium |
|---|---|
| Supply voltage | DC 5-24 V |
| Current consumption | 15 mA at 12 V DC |
| Interface | RS485 |
| Baud rate | 9600 bps |
| Temperature range | -40 to 80 °C |
| Temperature accuracy | ±0.5 °C |
| Moisture range | 0-100% |
| Moisture accuracy | ±5% |
| Electrical conductivity range | 0-10000 μS/cm |
| Electrical conductivity accuracy | ±10% |
| Npk range claimed | 0-2000 mg/kg |
| Npk accuracy claimed | ±2% (manufacturer claim; empirical conductivity-derived values, not direct nutrient analysis) |
| Ph range | 0-10 pH |
| Ph precision claimed | ±1 pH (reference only; manufacturer warns of instability) |
| Working environment temperature | -40 to 80 °C |
| Sealing material | Black epoxy resin |
| Dimensions | 138 ±1 mm long × 45 ±1 mm wide × 15 ±1 mm thick |
| Probe dimensions | 65 ±1 mm long × 3 ±0.2 mm diameter |
| Probe design | Five pins; material text describes three solid stainless-steel, one hollow stainless-steel and one zinc-alloy probe |
| Communication | 8 data bits, no parity; communication interval at least 1000 ms; Modbus read function 0x03 |
| Wiring | Red: power +; black: power -; yellow: RS485 +; blue: RS485 - |
| Registers | 0x0000: Temperature (example scaling 0.1 °C); 0x0001: Moisture (example scaling 0.1%); 0x0002: Conductivity (μS/cm); 0x0003: pH (example scaling 0.01 pH); 0x0004: N (mg/kg indicative); 0x0005: P (mg/kg indicative); 0x0006: K (mg/kg indicative) |
| Important note 1 | N/P/K values are empirical estimates derived from conductivity and configurable factors. The manufacturer states they cannot accurately measure actual on-site nitrogen, phosphorus and potassium content. |
|---|---|
| Important note 2 | The manufacturer states that pH data may be unstable and should be used as reference only; a glass-electrode pH sensor is recommended for more accurate measurement. |
| Important note 3 | N/P/K values are empirical estimates derived from soil electrical conductivity and configurable factors. The manufacturer states they cannot accurately measure actual on-site nitrogen, phosphorus and potassium concentrations. |
| Important note 4 | The manufacturer states that pH data may be unstable and is for reference only; a glass-electrode pH sensor is recommended for more accurate measurement. |
| Important note 5 | Manual states N/P/K outputs are conductivity-derived empirical estimates and cannot accurately measure actual soil nitrogen, phosphorus or potassium; pH is reference-only and may be unstable. |
| Important note 6 | pH range/accuracy differs between manual (0-10 pH, ±1 pH) and quotation/catalogue (3-10 pH, ±0.6 pH). Moisture accuracy differs across sources. Confirm selected hardware/firmware version. |
| Important note 7 | The manual gives pH range 0-10 and claimed precision ±1 pH; the catalogue/quotation give 3-10 and ±0.6 pH. The manual also warns that pH can be unstable and is for reference only. |
| Important note 8 | Moisture accuracy differs: catalogue ±3% versus quotation/manual ±5%. Confirm the actual supplied version. |
| Supplier | NiuBoL |
|---|---|
| Manufacturer model | NBL-S-TMC-7 |
| Price and availability | Confirmed by quotation |
| Warranty terms | Confirmed in the quotation |
| Data basis | Supplier-provided catalogue, quotation and available instruction manuals; values are source-specific. |
Select an image to view the full-resolution version.
Collect the stated plant or soil measurements for an agricultural monitoring project.
Evaluate the selected configuration against reference measurements before interpreting the data for a particular study.
Configuration-specific availability and pricing.
Specify the required model/configuration and confirm included components, compatibility, price, availability, delivery and warranty in the quotation.
Quotation requiredProducts, accessories, gateways and software designed to work with this product.
Support for product selection, deployment, integration and continued operation.
Share your application, sensing requirements, environment and expected integration scope with our engineering team.
Contact Adaptive AgroTechAdd it to the quotation basket and state the model, quantity, required configuration and intended measurement task. Price, availability, delivery and warranty are confirmed in the quotation.
Use the specification group for the selected source/configuration and review the confirmation notes. Where supplier files disagree, the exact version must be confirmed before ordering.
The supplied source files do not establish a universal package of included accessories. Confirm the required power, interface, mounting and cable options in the quotation.
N/P/K values are empirical estimates derived from conductivity and configurable factors. The manufacturer states they cannot accurately measure actual on-site nitrogen, phosphorus and potassium content. The manufacturer states that pH data may be unstable and should be used as reference only; a glass-electrode pH sensor is recommended for more accurate measurement. N/P/K values are empirical estimates derived from soil electrical conductivity and configurable factors. The manufacturer states they cannot accurately measure actual on-site nitrogen, phosphorus and potassium concentrations. The manufacturer states that pH data may be unstable and is for reference only; a glass-electrode pH sensor is recommended for more accurate measurement.
Add the required product configuration to your cart, then send the complete selection to Adaptive AgroTech sales. Custom sensors, quantities, installation, training and integration requirements can all be included.
Your selected configuration and quantity will be carried into the quotation request automatically.
Open Cart & Request Quote