Skip to content

Features & Benefits

Core capabilities and practical value for deployment.

✓

Product function

7-in-1 Soil Integration Sensor. Manufacturer model NBL-S-TMC-7.

✓

Technical data for selection

Review the source-specific ranges, interfaces and operating conditions below when specifying your required configuration.

✓

Supplier-stated supply voltage

DC 5-24V

✓

Configuration notes included

The overview and specification table retain supplier-document differences and applicable measurement limitations.

Included Capabilities

  • Stated product function
  • Configuration selection

Customer Benefits

  • Specifications available for comparison
  • Configuration captured in the request

Technical Specifications

Detailed technical data for evaluation and system integration.

Supplier-stated technical data — quotation

Supply VoltageDC 5-24V
OutputRS485
Temperature range-40-80 ℃
Temperature accuracy±0.5 ℃
Moisture range0%-100%
Moisture accuracy±5%
Conductivity range0-10000us/cm
Conductivity Accuracy±10%
NPK range0-2000mg/Kg
Accuracy of NPK±2%
PH range3-10pH
PH precision±0.6pH
Protection classIP68
RemarkSoil NPK sensor actually measures the electrical conductivity of the soil.

Catalogue page 31 — technical data

Soil temperature range-40~80℃ Resolution: 0.1, Accuracy: ±0.5
Soil moisture range0-100%RH Resolution: 0.1%RH, Accuracy: ±3%
Conductivity range0-10000us/cm.Accuracy: ±10%
NPK range:0-2000mg/Kg Accuracy of NPK: ±2%
PH effective range:3-10PH PH precision: ±0.6PH
Supply voltageDC5V-24V □ DC12V-24V
Signal output□RS485
Protection classIp68 submerged in water for long-term use
Operating environment-40~80℃
Sealing materialBlack flame retardant epoxy resin
Supplier statementLnstallation method: all buried or all probes are inserted into the measured medium
Supplier statementDefault cable length: 5 meters, cable length can be customized
Connection methodPre-assembled cold-pressed terminals
Meamethodsurement principle:Soil moisture FDR
Electrode length65mm

Instruction-manual data — source-specific

Measured outputsSoil temperature, moisture, electrical conductivity, pH, nitrogen, phosphorus, potassium
Supply voltageDC 5-24 V
Current consumption15 mA at 12 V DC
InterfaceRS485
Baud rate9600 bps
Temperature range-40 to 80 °C
Temperature accuracy±0.5 °C
Moisture range0-100%
Moisture accuracy±5%
Electrical conductivity range0-10000 μS/cm
Electrical conductivity accuracy±10%
Npk range claimed0-2000 mg/kg
Npk accuracy claimed±2% (manufacturer claim; empirical conductivity-derived values, not direct nutrient analysis)
Ph range0-10 pH
Ph precision claimed±1 pH (reference only; manufacturer warns of instability)
Working environment temperature-40 to 80 °C
Sealing materialBlack epoxy resin
Dimensions138 ±1 mm long × 45 ±1 mm wide × 15 ±1 mm thick
Probe dimensions65 ±1 mm long × 3 ±0.2 mm diameter
Probe designFive pins; material text describes three solid stainless-steel, one hollow stainless-steel and one zinc-alloy probe
Communication8 data bits, no parity; communication interval at least 1000 ms; Modbus read function 0x03
WiringRed: power +; black: power -; yellow: RS485 +; blue: RS485 -
Registers0x0000: Temperature (example scaling 0.1 °C); 0x0001: Moisture (example scaling 0.1%); 0x0002: Conductivity (μS/cm); 0x0003: pH (example scaling 0.01 pH); 0x0004: N (mg/kg indicative); 0x0005: P (mg/kg indicative); 0x0006: K (mg/kg indicative)

Configuration confirmation and measurement limitations

Important note 1N/P/K values are empirical estimates derived from conductivity and configurable factors. The manufacturer states they cannot accurately measure actual on-site nitrogen, phosphorus and potassium content.
Important note 2The manufacturer states that pH data may be unstable and should be used as reference only; a glass-electrode pH sensor is recommended for more accurate measurement.
Important note 3N/P/K values are empirical estimates derived from soil electrical conductivity and configurable factors. The manufacturer states they cannot accurately measure actual on-site nitrogen, phosphorus and potassium concentrations.
Important note 4The manufacturer states that pH data may be unstable and is for reference only; a glass-electrode pH sensor is recommended for more accurate measurement.
Important note 5Manual states N/P/K outputs are conductivity-derived empirical estimates and cannot accurately measure actual soil nitrogen, phosphorus or potassium; pH is reference-only and may be unstable.
Important note 6pH range/accuracy differs between manual (0-10 pH, ±1 pH) and quotation/catalogue (3-10 pH, ±0.6 pH). Moisture accuracy differs across sources. Confirm selected hardware/firmware version.
Important note 7The manual gives pH range 0-10 and claimed precision ±1 pH; the catalogue/quotation give 3-10 and ±0.6 pH. The manual also warns that pH can be unstable and is for reference only.
Important note 8Moisture accuracy differs: catalogue ±3% versus quotation/manual ±5%. Confirm the actual supplied version.

Ordering and attribution

SupplierNiuBoL
Manufacturer modelNBL-S-TMC-7
Price and availabilityConfirmed by quotation
Warranty termsConfirmed in the quotation
Data basisSupplier-provided catalogue, quotation and available instruction manuals; values are source-specific.

Applications

Select an image to view the full-resolution version.

Application image coming soon

Agricultural observations

Collect the stated plant or soil measurements for an agricultural monitoring project.

Application image coming soon

Research and integration trials

Evaluate the selected configuration against reference measurements before interpreting the data for a particular study.

Available Configurations

Configuration-specific availability and pricing.

Default

7-in-1 Soil Integration Sensor — quotation configuration

Specify the required model/configuration and confirm included components, compatibility, price, availability, delivery and warranty in the quotation.

Quotation required

Documentation & Downloads

7-in-1 Soil Integration Sensor — supplier datasheetDatasheet
—enpublicOpen

Compatibility & Ecosystem

Products, accessories, gateways and software designed to work with this product.

Compatibility information is being prepared.
Please contact Adaptive AgroTech to confirm accessories, gateways, software, or integration requirements for this product.

Technical Support

Support for product selection, deployment, integration and continued operation.

Discuss your deployment

Share your application, sensing requirements, environment and expected integration scope with our engineering team.

Contact Adaptive AgroTech

Support Options

  • Installation and commissioning
  • Calibration and repair
  • Remote diagnostics
  • Training and integration
How do I request this product?

Add it to the quotation basket and state the model, quantity, required configuration and intended measurement task. Price, availability, delivery and warranty are confirmed in the quotation.

Which specifications apply to the supplied version?

Use the specification group for the selected source/configuration and review the confirmation notes. Where supplier files disagree, the exact version must be confirmed before ordering.

Are power, cabling and other accessories included?

The supplied source files do not establish a universal package of included accessories. Confirm the required power, interface, mounting and cable options in the quotation.

What measurement or configuration limitations should I check?

N/P/K values are empirical estimates derived from conductivity and configurable factors. The manufacturer states they cannot accurately measure actual on-site nitrogen, phosphorus and potassium content. The manufacturer states that pH data may be unstable and should be used as reference only; a glass-electrode pH sensor is recommended for more accurate measurement. N/P/K values are empirical estimates derived from soil electrical conductivity and configurable factors. The manufacturer states they cannot accurately measure actual on-site nitrogen, phosphorus and potassium concentrations. The manufacturer states that pH data may be unstable and is for reference only; a glass-electrode pH sensor is recommended for more accurate measurement.

Project Sales

Request a Formal Quotation

Add the required product configuration to your cart, then send the complete selection to Adaptive AgroTech sales. Custom sensors, quantities, installation, training and integration requirements can all be included.

Build your quotation from the cart

Your selected configuration and quantity will be carried into the quotation request automatically.

Open Cart & Request Quote

Product image