A 555 Timer That Remembers When to Fill a Tank | Two Float Switches
Two float switches give a tank filler separate start and stop levels. A 555 latch keeps the pump command steady as the level passes between them.
The key idea
The lower float sets the latch when the tank needs water. Once filling begins, rising water can leave the lower float behind and the pump keeps running until the upper float resets the latch.
What to remember
- At an intermediate level, the pump state depends on which boundary water crossed last.
- A larger gap between floats generally lengthens each filling cycle.
Check your understanding
At halfway full, how can you tell whether the controller is running the pump?
Show the explanation
Check the latch state or which float was triggered last. The same halfway level occurs during both filling and draining.