Skip to content
Adaptive AgroTech NetworkUniversity of Southern Denmark · SDU Drone Center
Cover for A 555 Timer That Remembers When to Fill a Tank | Two Float Switches

Video by Adaptive AgroTech. If the embedded player is unavailable, open the original video ↗.

A 555 Timer That Remembers When to Fill a Tank | Two Float Switches

Two float switches give a tank filler separate start and stop levels. A 555 latch keeps the pump command steady as the level passes between them.

Understand the concept

The key idea

The lower float sets the latch when the tank needs water. Once filling begins, rising water can leave the lower float behind and the pump keeps running until the upper float resets the latch.

What to remember

  • At an intermediate level, the pump state depends on which boundary water crossed last.
  • A larger gap between floats generally lengthens each filling cycle.
Pause & think

Check your understanding

At halfway full, how can you tell whether the controller is running the pump?

Show the explanation

Check the latch state or which float was triggered last. The same halfway level occurs during both filling and draining.