Measured Water Dispensing | Load Cell, Fast Fill & Slow Approach
A load cell tracks the water mass delivered into a container. Fast filling shortens the bulk stage, while a slower final approach reduces the amount still arriving when flow stops.
The key idea
Taring the empty container makes the measurement refer to dispensed water. Sensor filtering and liquid already in transit introduce delay, so the final settled mass is a better basis for tuning the cutoff than the reading at the instant of shutoff.
What to remember
- Choose the transition to slow filling before the target mass.
- Compare settled mass against the target over repeated fills.
Check your understanding
Why can the final mass exceed the target even if the controller stops at the target reading?
Show the explanation
Liquid already in transit continues into the container, and filtering can make the displayed mass lag the actual mass.