Battery Undervoltage Disconnect | Comparator & Hysteresis
A comparator can disconnect a load when battery voltage falls below a threshold. Hysteresis introduces a higher threshold for reconnecting it.
The key idea
A loaded battery can recover some terminal voltage as soon as the load disconnects. With a single switching threshold, that rebound can reconnect the load and immediately cause another drop.
What to remember
- The lower threshold controls disconnection.
- The upper threshold sets the recovery needed before reconnection.
Check your understanding
The load repeatedly switches on and off near an empty battery. What sets the needed separation between thresholds?
Show the explanation
Consider the expected voltage rebound after disconnection and the sag when the load returns, along with ordinary measurement noise.