Skip to content
Adaptive AgroTech NetworkUniversity of Southern Denmark · SDU Drone Center
Cover for How Can a Long Interrupt Handler Break Real-Time Control?

Video by Adaptive AgroTech. If the embedded player is unavailable, open the original video ↗.

How Can a Long Interrupt Handler Break Real-Time Control?

Time spent in an interrupt handler can delay other work with deadlines.

Understand the concept

The key idea

Time spent in an interrupt handler can delay other work with deadlines. An infrequent slow path can introduce jitter even when average CPU utilization looks low.

What to remember

  • Measure worst-case execution time
  • Defer lengthy processing when deadlines permit
Pause & think

Check your understanding

Why can a rare long handler disrupt a periodic controller?

Show the explanation

Its delay can push one control update past its deadline.