Test a Battery Under Load | Voltage Sag Beyond Open-Circuit Readings
Battery terminal voltage can fall when a load draws current and recover after the load is removed. Comparing open-circuit and loaded readings reveals this voltage sag.
The key idea
A simple short-duration model relates the voltage change to load current and effective series resistance. Contact resistance, temperature and measurement timing can all influence the observed drop.
What to remember
- Record current along with voltage for a meaningful comparison.
- Use the same measurement location and timing across tests.
Check your understanding
Two batteries have the same open-circuit voltage. Why might only one power a device reliably?
Show the explanation
The other may have greater voltage sag at the device's operating current, dropping its terminal voltage below the required level.