Skip to content
Adaptive AgroTech NetworkUniversity of Southern Denmark · SDU Drone Center
Cover for Why Can Timer Capture Beat Software Pulse Timing?

Video by Adaptive AgroTech. If the embedded player is unavailable, open the original video ↗.

Why Can Timer Capture Beat Software Pulse Timing?

Timer input capture latches the counter value when an input edge occurs.

Understand the concept

The key idea

Timer input capture latches the counter value when an input edge occurs. Software can read the timestamp after interrupt service begins.

What to remember

  • Capture successive edge timestamps
  • Account for counter rollover
Pause & think

Check your understanding

Why does delayed interrupt service have less effect on a captured timestamp?

Show the explanation

Hardware recorded the time at the edge before the handler ran.